Wanbo Group Instruments · Authorized Test & Measurement Supplier
From pre-test checks, power-off and discharge, wiring and voltage selection to stable readings and instrument maintenance, practical tips for automotive insulation testing.
Measuring insulation resistance with the Fluke 1508 is straightforward, but avoiding mistakes requires attention to detail.
Inspect the instrument: check test leads for cuts and ensure alligator clips grip firmly—damaged leads cause fluctuating readings. Weak AA batteries also skew data, so keep spares. The device under test (e.g. a battery pack) must be powered off and discharged for at least 10 minutes (longer for capacitive parts); confirm zero voltage with a DMM before testing.
For a motor: connect L to the winding and E to the frame, making good contact (not on painted surfaces). Choose 1000 V range for motors above 500 V, 500 V range below. After pressing test, wait about one minute for stabilization—early fluctuations come from capacitive current. If the reading is below the threshold (e.g. below 0.25 MΩ for a 500 V motor), stop and check for damaged harnesses or moisture.
Store leads neatly, wipe the body, and keep it in a dry case. Remove batteries during long storage to prevent leakage, and calibrate annually.