A regenerative load rectifies and inverts the DUT energy back to the grid, saving power with high-quality output. This article covers its principle, difference from dissipative loads and safety protection.
As technology advances and energy demand grows, efficient and energy-saving power test equipment is increasingly needed in industry and labs. With unique energy-recovery capability and excellent performance, regenerative electronic loads are an ideal choice in many fields.
Take a battery drawing about 30kW: DC power first enters the IT8000's internal DC-DC converter for conditioning, then an inverter converts it to AC that meets local grid voltage and frequency. The recovered energy feeds back into the factory grid for internal users (e.g. charging battery 2), so only 21.5kVA extra is drawn from the utility. If regeneration exceeds internal consumption, surplus power goes to nearby users over the public grid. The IT8000 delivers near-sinusoidal feedback with iTHD below 5% and records recovered energy.
Regenerative loads suit single-process or long-duration loading, such as fuse endurance, power-module burn-in and chip aging. Dissipative loads suit electrical-performance tests of conversion modules—dynamic response, input/output accuracy, load/line regulation. Dissipative loads slew at 2.5-30A/μs, whereas regenerative loads are typically ~500Hz (ms-level), so dissipative loads better simulate fast transient, high-precision loads.
The IT8000 series offers frequency/phase locking and passive anti-islanding protection. When grid frequency or voltage fluctuation exceeds regulatory limits, it automatically shuts off input, stops loading and stops feeding energy back. The AC side also provides anti-islanding, under/over-frequency, under/over-voltage, over-current and phase-loss protection. ITECH regenerative loads cover 200W to 2MW.