Wanbo Group Instruments · Authorized Test & Measurement Supplier
Contrasting point measurement, covers burden-surface monitoring, cooling-stave diagnosis and tuyere monitoring, plus optical protection, radiometric correction, AI alerts and selection criteria.
Blast furnaces exceed 1500°C; thermocouples offer only dozens of points over thousands of m², insert devices are short-lived, and spot IR pyrometers give no thermal image.
Top-, shaft- or tuyere-mounted IR cameras deliver 2D temperature maps, upgrading measurement from points to surfaces and from discrete data to continuous images, detecting stave water leaks, wall accretion and local hot gas channels.
Optical windows must withstand heat and shock, with air/nitrogen purge and water/air cooling. A radiative-transfer correction model plus dual/multi-band pyrometry counters CO, CO₂, steam and dust. Cameras integrate with the L2 process system and burden/condition models.