1. Operating procedure
1. Insert the positive and negative connectors into the corresponding rear-panel terminals (positive: handle probe; negative: crocodile clip).
2. Turn on the rear power switch.
3. Touch the front-panel ON switch to start.
4. Turn the knob to set the detection voltage between 3kV and 5kV.
5. Connect the negative crocodile clip to the metal part of the device under test.
6. Select the appropriate detection head and connect it to the positive handle.
7. Move the detection head across the insulation layer; when damage is found, the beeper and flashing alarm lamp indicate a fault.
8. After use, turn off the power switch.
2. Maintenance
1. Wipe the exterior daily with a disinfectant wipe.
2. Check remaining battery level regularly and recharge.
3. Replace the battery periodically.
3. Safety notes
1. Do not touch both poles at once while powered; 3-5kV gives a slight tingle and 8kV a stronger one, but neither harms the human body.
2. Before first use or after long storage, fully charge for 8 hours. If the display flashes below 10%, recharge promptly.
3. When not in use, turn off the rear boat switch (standby current still drains the battery). If unused for over three months, remove and recharge for 8 hours before storage to avoid battery damage.
4. Always turn off the boat switch after use.