Wanbo Group Instruments · Authorized Test & Measurement Supplier
Measuring cell insulation resistance before electrolyte filling detects metallic foreign matter and separator damage early in production.
By measuring the insulation resistance of lithium-ion battery cells before electrolyte is poured in, it is possible to detect the presence of metallic foreign matter and damage to the separator at an early stage of the production process.
For LIBs, insufficient insulation resistance means areas that should be electrically insulated are not, reducing battery life and increasing combustion risk. The primary causes are metallic foreign contaminants and separator damage. Fine metal slivers from electrode cutting pierce the electrode and separator, while scratches or cuts during production reduce insulation. Both create paths for unwanted current; the resulting heat can lead to ignition.
Apply a voltage through areas that should be insulated; if electricity flows too well, a defect exists. This is the insulation resistance test. Finding defects early avoids assembling good parts onto faulty ones. The earliest effective step is after cell assembly but before electrolyte filling, since applying voltage afterward damages the battery.
Insulation resistance must be measured at three points: between the two electrodes (before electrolyte filling) and between any point on the enclosure and each of the two electrodes (after filling).