Wanbo Group Instruments · Authorized Test & Measurement Supplier
As lithium-ion batteries scale up in EVs and ESS, fires rise with energy density and fast charging. Insulation testing should verify electrode spacing rather than just resistance.
Soaring energy demand and performance have made lithium-ion batteries ubiquitous in EVs and renewable energy storage (ESS). Yet rising usage, energy density and fast charge/discharge rates have increased fire and explosion incidents.
1. Why are most lithium-ion battery fires hard to analyze? Reports often cite electrical control errors or lithium metal deposition growing into dendrites that cause internal short circuits. While possible, most rapid chemical combustion accidents are hard to pin down to a single cause.
2. Root cause of most fires? Most lithium-ion fires (including in EVs) happen during charging. The main cause is expansion of the anode (graphite or silicon blend) after repeated cycles, shortening the distance between electrodes. With burrs or metal particles present, the effective gap becomes smaller than designed, raising internal short-circuit risk.
3. Why are defects hard to catch in normal production? A common problem in cell inspection is that jelly-roll insulation test voltage is too low (<350V) and cannot detect flashover caused by burrs or particles. From a fire-safety view, cell insulation testing should check the electrode spacing rather than just measure insulation resistance. Air breakdown voltage exceeds 350V even at gaps of a few um, so test voltage should be above 350V.
4. How to set the test voltage? Recent Chroma tests on commercial separator withstand voltage (WV) show normal products at ~800-1200V, shorted products detected easily below 250V, partially-damaged separators at ~450-700V. A test limit of 250V only catches hard shorts, not partial damage.
5. Solution: the Chroma 11210 cell insulation tester. It adds a +Flash test: first a short high voltage, then a second higher voltage stage to verify electrode spacing. A long low-voltage step detects abnormal leakage from fine particles or defects in the separator. The +Flash function covers both conditions in one fast, complete test, lowering lithium-ion fire risk.