Following HKCI TM 1:2022, a Guide PT-II flagship thermal camera non-destructively scanned facades to precisely locate hollowing for targeted, minimally invasive repair.
Hong Kong has many high-rises whose facades suffer hidden hollowing/delamination under heat, humidity and typhoon rain. The project followed HKCI TM 1: Issue 2:2022. Traditional tap-and-visual inspection is difficult, slow and unreliable on tall buildings.
A Guide PT-II flagship thermal camera scanned the facade. Clear, regular thermal anomalies indicate real hollowing; larger and more concentrated temperature gaps mean worse delamination; uniform temperature means solid bonding. PC-based ThermoTools software filters environmental interference to pinpoint defect points.
Detects early micro-hollowing before spalling, enables targeted minimally invasive repair, and archives thermal images and measurements as traceable quality evidence that complies with HKCI guidance.