Wanbo Group Instruments · Authorized Test & Measurement Supplier
DPT theory, three-stage waveforms, turn-on/turn-off and reverse-recovery definitions, and a practical setup using the AFG31000 and 4/5/6 Series MSO.
Power semiconductors are transitioning from silicon to wide-bandgap SiC and GaN, enabling smaller, faster and more efficient designs. Switching losses are inevitable, so engineers must rigorously measure switch timing and associated energy losses. The preferred method is the Double Pulse Test, described in JEDEC JEP182, JESD24-10 and IEC 60747-9/-8.
DPT measures switching parameters and evaluates dynamic behavior under controlled voltage, current and temperature. Pulses limit self-heating and keep junction temperature stable. Goals include measuring turn-on parameters (td(on), tf, ton, ID, dv/dt, di/dt, Eon, dynamic RDS(on)), turn-off parameters (td(off), tr, toff, VDSM, Eoff, Qoss), and reverse recovery (trr, irr, Qrr, Err, di/dt, VSD).
Energy loss is computed by integrating instantaneous power (VDS × ID) over turn-on and turn-off. Reverse recovery current flows briefly as the diode switches from forward to reverse bias, adding Qrr and Err loss.
Warning: power-semiconductor tests involve lethal voltages/currents; use enclosures with safety interlocks and PPE. Typical setup: an AFG (e.g. AFG31000 with DPT app) for gate pulses, a high-voltage DC supply for VDD, a multi-channel oscilloscope to capture VDS/VGS/ID, and probes — e.g. IsoVu isolated voltage/current probes for high-side floating measurements and a clamp-on current probe for the load inductor.